MAINTENANCE
Tennant 5300 (1100)
46
3. Lift up the recovery tank to get access to the
batteries.
NOTE: The recovery tank must be empty.
4. Before charging batteries, check the
electrolyte level in all the battery cells. If the
level is low, add just enough distilled water
to cover the plates, level (A). Never add acid
to batteries. DO NOT OVERFILL. The
batteries can overflow during charging due
to expansion.
Do not charge batteries unless fluid is
slightly above battery plates (A).
NOTE: Make sure the battery caps are in place
while charging.
FOR SAFETY: When servicing machine, avoid
contact with battery acid.
5. Plug the charger connector into the battery
connector.
WARNING: Batteries emit hydrogen
gas. Explosion or fire can result. Keep
sparks and open flame away. Keep covers
open when charging.
6. Plug the battery charger into the wall outlet.
NOTE: If the red “ABNORMAL CYCLE” lamp
lights when charger is plugged into a wall outlet,
the charger can not charge the battery, and there
is something wrong with the battery.
7. The charger will start automatically. When
the batteries are fully charged, the charger
will automatically turn off.
09510
A
09520
07224